Humidifier capacity | 4 liters |
Upgrade your Boomr Bin Monotub with this automated tech kit, featuring a fresh air fan, humidifier with hose, monotub hose connector, and humidity controller with sensor. This easy-to-install kit allows you to upgrade your Boomr Bin to allow for better control of humidity, CO2 levels, and fresh air exchange. Plus, the fan also includes a removable washable screen for better spore filtration.
Tech kit includes:
- (1) FAE Fan Mini w/ Power Control
- (1) Myco-Mister Mini Humidifier w/ hose
- (1) Monotub Hose Connector
- (1) MYCOntroller Humidity Controller (Hygrometer)
Using tech kit:
- Once monotub is fully colonized, remove the self-adhesive filters on one end of the lid to hook up the FAE Fan Mini and Myco-Mister Mini Humidifier with hose.
- On the opposite end of the lid, cut a one-inch slice into the 2" filter and slide the MYCOntroller Humidity Controller probe inside.
- These additions will allow you to optimize fresh air exchange, CO2 levels, and humidity levels for the specific species you are growing.
Important notice:
⚠️ Using tap water with a high mineral content (aka "hard water") with any humidifier can cause a fine white dust build to up and/or to be emitted. To avoid this, use distilled or demineralized water. Or, add a demineralization cartridge to the water tank. (This can be done by removing the top cover and placing the cartridge inside.)
-
Myco-Mister Mini Humidifier
- Capacity: 4L
- 110-240V; 50/60Hz
- Max Usage Area: 215 Sq ft
- Max Evaporation: 380ml/H
FAE Fan Mini
- 110-220VAC/50Hz
- 0.05A (Max. 0.06A)
FAE Fan Power Controller
- AC/DC Adapter
- Input: AC100-240V; 50/60Hz
- Output: 3V-12V—2A
MYCOntroller Humidity Controller
- 110-220V
- Measurement range: 0%RH-99%RH
- Control accuracy: 0.1%RH
- Output type: Direct output
- Output capacity: Max 10A
-
- First, plug the humidity controller device into wall.
- Next, set humidity range.
- Press and hold the "UP" button for 3 seconds, and the humidity value will flash. Set the high value. (For example, 90%)
- Wait for a few seconds to automatically return to main interface.
- Press and hold the "DOWN" button for 3 seconds, and the humidity value will flash. Set the low value. (For example, 75%)
- Finally, plug humidifier into device.
- Humidifier will turn ON when device falls below the lowest humidity setting and OFF when it reaches the highest humidity setting.
-
WARNING: Do not clean humidifier while the unit is switched on. Turn off the power and unplug the unit from its power source before any cleaning or maintenance.
HUMIDIFIER WATER TANK
- DO NOT leave water sitting stagnant in tank for more than a couple of days as it may cause bacterial growth. Always empty tank if not planning to use it for a few days.
HUMIDIFIER STORAGE
- When not in use, store in a cool dry location in original packaging or completely covered (to prevent dust buildup).
- If water is left in the unit during storage, it may harden and leave deposits that may affect the unit from operating properly.
- Leave the cap of the water tank loose during storage. This will prolong the life of the gasket.
HUMIDIFIER CLEANING
- DO NOT use detergents or chemicals to clean the tank or base as it can interfere with the mist.
- If the water tank is dirty, soak it with a mild bleach and water solution (1 cup of bleach + 1 gallon of water) and rinse clean.
- Wipe the exterior of the body with a damp cloth.
- Clean and rinse the water tank and mist nozzle with lukewarm water frequently to avoid mineral buildup.
- Keep the nebulizer and water sensor free of mineral deposits.
- Only clean the nebulizer and sensor with a soft brush (e.g. soft toothbrush).
- DO NOT scrape the nebulizer or water sensor to avoid damage.
- DO NOT clean with tools that have metal parts.
- DO NOT spray water or any liquids onto the control knob.
- NEVER immerse the base in water or let water enter other openings.